Part Number Hot Search : 
CM6903A 1N5522A 1021T1 08JR5 LP2950C FDS7066 80400 LX1670
Product Description
Full Text Search
 

To Download 6SE6400-0EN00-0AA0 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 s Ordering Data for Variant Independent Options
Thewww..com suitable options listed here are for all MICROMASTER 440 Inverters.
Options Basic Operator Panel (BOP) Advanced Operator Panel (AOP) PROFIBUS module DeviceNet module Pulse encoder evaluation module RS485/PROFIBUS bus connector Connection set for PC to inverter Connection set for PC to AOP Inverter-door mounting kit for single inverter control AOP-door mounting kit for multiple inverter control (USS) Order No. 6SE6400-0BP00-0AA0 6SE6400-0AP00-0AA0 6SE6400-0AP00-0AA1 (available from mid 2002) 6SE6400-1PB00-0AA0 6SE6400-1DN00-0AA0 6SE6400-0EN00-0AA0 6GK1500-0FC00 6SE6400-1PC00-0AA0 6SE6400-0PA00-0AA0 6SE6400-0PM00-0AA0 6SE6400-0MD00-0AA0
Technical data of the communications modules
PROFIBUS module 6SE6400-1PB00-0AA0 DeviceNet module 6SE6400-1DN00-0AA0
Size (height x width x depth) Degree of protection Degree of pollution Mechanical strength * Stationary * Transport
Deflection Acceleration Deflection Acceleration
Climatic category (during operation) Cooling method Permissible ambient or cooling agent temperature * in operation * during storage and transport Relative humidity (permissible humidity rating) * in operation * during storage and transport Electromagnetic compatibility Emission Interference radiation Supply voltage
161 mm x 73 mm x 46 mm IP 20 2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation to DIN IEC 60 068-2-6 (if module installed correctly) 0.15 mm in the frequency range of 10 Hz to 58 Hz 19.6 m/s2 in the frequency range of 58 Hz to 500 Hz 3.5 mm in the frequency range of 5 Hz to 9 Hz 9.8 m/s2 in the frequency range of 9 Hz to 500 Hz 3K3 to DIN IEC 60 721-3-3 Natural air cooling -10 C to +50 C (14 F to 122 F) -25 C to +70 C (-13 F to 158 F) 85 % (non-condensing) 95 % to EN 55 011 (1991) Class A to IEC 60 801-3 and EN 61 000-4-3 6.5 V 5 %, max. 300 mA, internal from inverter or 24 V 10 %, max. 350 mA, external 5 V 10 %, max. 100 mA, galvanically isolated supply * for terminating the serial interface bus or * for supplying the OLP (Optical Link Plug) max. 12 Mbaud 6.5 V 5 %, max. 300 mA internal from inverter or 24 V, max. 60 mA from DeviceNet bus -
Output voltage
Data transmission rate
125, 250 and 500 kbaud
Variant Independent Options
Technical data of the pulse encoder evaluation module www..com
Pulse encoder evaluation module 6SE6400-0EN00-0AA0
Size (height x width x depth) Degree of protection Degree of pollution Mechanical strength * Stationary * Transport
Deflection Acceleration Deflection Acceleration
Climatic category (during operation) Cooling method Permissible ambient or cooling agent temperature * in operation * during storage and transport Electromagnetic compatibility Emission Interference radiation Relative humidity (permissible humidity rating) * in operation * during storage and transport Supply voltage Pulse frequency
161 mm x 73 mm x 42 mm IP 20 2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation to DIN IEC 60 068-2-6 (if module installed correctly) 0.15 mm in the frequency range of 10 Hz to 58 Hz 19.6 m/s2 in the frequency range of >58 Hz to 500 Hz 3.5 mm in the frequency range of 5 Hz to 9 Hz 9.8 m/s2 in the frequency range of 9 Hz to 500 Hz 3K3 to DIN IEC 60 721-3-3 Natural air cooling -10 C to +50 C (14 F to 122 F) -20 C to +70 C (-14 F to 158 F) to EN 55 011 (1991) Class A to IEC 60 801-3 and EN 61 000-4-3 85 % (non-condensing) 95 % 5 V 5 %, 330 mA or 18 V non-regulated, 140 mA, short-circuit-proof max. 300 kHz
Documentation
Type of documentation Docu-Pack, supplied with each inverter, containing CD-ROM 1) and Getting Started Guide 2) (paper version) Operating instruction2) (paper version) Language Multilanguage Order No. 6SE6400-5AD00-1AP0 6SE6400-5AC00-1AP0 (available from 05/2002)
Parameter list 2) (paper version)
German English French Italian Spanish German English French Italian Spanish
6SE6400-5AC00-0AP0 6SE6400-5AC00-0BP0 6SE6400-5AC00-0DP0 6SE6400-5AC00-0CP0 6SE6400-5AC00-0EP0 6SE6400-5BB00-0AP0 6SE6400-5BB00-0BP0 6SE6400-5BB00-0DP0 6SE6400-5BB00-0CP0 6SE6400-5BB00-0EP0
1) The CD-ROM contains operating instructions, parameter list, commissioning tools Starter and DriveMonitor, multilanguage.
2) Available on Internet at http://www.siemens.com/ micromaster.


▲Up To Search▲   

 
Price & Availability of 6SE6400-0EN00-0AA0

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X